Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.12188/22661
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Vićentić, Teodora | en_US |
dc.contributor.author | Rašljić Rafajilović, Milena | en_US |
dc.contributor.author | Ilić, Stefan | en_US |
dc.contributor.author | Koteska, Bojana | en_US |
dc.contributor.author | Madevska Bogdanova, Ana | en_US |
dc.contributor.author | Pašti, Igor | en_US |
dc.contributor.author | Lehocki, Fedor | en_US |
dc.date.accessioned | 2022-08-29T08:01:10Z | - |
dc.date.available | 2022-08-29T08:01:10Z | - |
dc.date.issued | 2023-08 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.12188/22661 | - |
dc.description.abstract | The HeartPy Python toolkit for analysis of noisy signals from heart rate measurements is an excellent tool to use in conjunction with novel wearable sensors. Nevertheless, most of the work to date has focused on applying the toolkit to data measured with commercially available sensors. We demonstrate the application of the HeartPy functions to data obtained with a novel graphene-based heartbeat sensor. We produce the sensor by laser-inducing graphene on a flexible polyimide substrate. Both graphene on the polyimide substrate and graphene transferred onto a PDMS substrate show piezoresistive behavior that can be utilized to measure human heartbeat by registering median cubital vein motion during blood pumping. We process electrical resistance data from the graphene sensor using HeartPy and demonstrate extraction of several heartbeat parameters, in agreement with measurements taken with independent reference sensors. We compare the quality of the heartbeat signal from graphene on different substrates, demonstrating that in all cases the device yields results consistent with reference sensors. Our work is a first demonstration of successful application of HeartPy to analysis of data from a sensor in development. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Sensors | en_US |
dc.relation.ispartofseries | 22(17);6326 | - |
dc.subject | bioinformatics | en_US |
dc.subject | biomedical electronics | en_US |
dc.subject | biomedical materials | en_US |
dc.subject | biomedical signal processing | en_US |
dc.subject | biosensors | en_US |
dc.subject | medical information systems | en_US |
dc.subject | wearable sensors | en_US |
dc.title | Laser-Induced Graphene for Heartbeat Monitoring with HeartPy Analysis | en_US |
dc.type | Journal Article | en_US |
dc.identifier.doi | 10.3390/s22176326 | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
crisitem.author.dept | Faculty of Computer Science and Engineering | - |
crisitem.author.dept | Faculty of Computer Science and Engineering | - |
Appears in Collections: | Faculty of Computer Science and Engineering: Journal Articles |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.