Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12188/2357
Title: Application of base isolation systems at plan irregular structures
Authors: Volcev, Riste
Todorov, Koce 
Lazarov, Ljupco
Keywords: Eurocode 8, plan irregularity, seismicity, base isolation, dynamic analysis
Issue Date: Oct-2017
Publisher: Macedonian Association of Structural Engineers
Series/Report no.: 17;pp. 544-555
Conference: 17 International symposium of MASE, Ohrid 2017
Abstract: Application of base isolation systems is one of the possible solutions to avoid the negative effects from irregularity of structures in plan. In order to investigate the advantages of the application of these systems, a detailed evaluation of the behaviour of six spatial five storey structures with different level of plan irregularity and different shapes in plan was performed. All structures are analysed as fixed base and base isolated. At irregular structures with rectangular shape in plan, base isolation significantly reduces eccentricity between the centre of stiffness and the centre of mass. Oppositely, in structures with “T” shape, eccentricity is larger at base isolated models. The maximal interstorey drifts of base isolated models are about 2,5 times smaller in comparison with the fixed base.
URI: http://hdl.handle.net/20.500.12188/2357
ISBN: 978-608-4510-32-1
Appears in Collections:Faculty of Civil Engineering: Conference papers

Show full item record

Page view(s)

128
checked on Jul 24, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.