Наслов: | Comparison of 24 h ECG Holter Monitoring with Real-time Long-term ECG Monitoring System using ECGalert Software and Savvy Single-Lead Patch | Authors: | Lidija Poposka Marija Vavlukis Hristo Pejkov Marjan Gushev |
Keywords: | the single-channel ECGalert system glycaemia HbA1c |
Issue Date: | 5-јан-2021 | Publisher: | Scientific Foundation SPIROSKI | Journal: | Open Access Macedonian Journal of Medical Sciences | Abstract: | AIM: The aim of the study was to show non-inferiority of the single-channel ECGalert system to the gold standard (ECG Holter) in the detection of arrhythmias over the total wear time of both devices. METHODS: A prospective study enrolled a total of 165 patients hospitalized at the University Clinic of Cardiology, who underwent simultaneous single-channel ECG recording with ECGAlert system and a conventional 24 h Holter monitor on the 1st day and continued ECGAlert monitoring for few more days, under assignment of the doctor or at the wish of the patient. RESULTS: A total of 165 patients were included in the study, 61.2% male, mean age of 58.4 ± 12.7 years. Mean duration of ECG Holter monitoring was 23.2 ± 0.5 h and mean duration of ECGalert/Savvy monitoring was 64.6 ± 31.2. During the first 24 h of simultaneous ECG monitoring with both methods, no statistically significant difference was found in arrhythmia detection. Over the total wear time of both devices, the ECGalert system detected significantly more AF episodes as compared to Holter (p < 0.000). ECGalert demonstrated significantly lower detection rate of false pauses (0.001). However, false detection of episodes of VT or AF was significantly higher in ECGalert system versus Holter (p < 0.000 and p < 0.000 respectively). Patients were more satisfied with ECGalert system, due to lesser interference in daily activities. CONCLUSION: The ECGalert system demonstrated superiority over traditional Holter monitoring in arrhythmia detection in the total monitoring period, but not in the first 24 h.</jats:p> | URI: | http://hdl.handle.net/20.500.12188/12713 | DOI: | 10.3889/oamjms.2021.4960 |
Appears in Collections: | Faculty of Medicine: Conference papers |
Files in This Item:
File | Опис | Size | Format | |
---|---|---|---|---|
10.3889_oamjms.2021.4960.pdf | 1.9 MB | Adobe PDF | View/Open |
Page view(s)
85
checked on 24.7.2024
Download(s)
14
checked on 24.7.2024
Google ScholarTM
Проверете
Altmetric
Записите во DSpace се заштитени со авторски права, со сите права задржани, освен ако не е поинаку наведено.