Ве молиме користете го овој идентификатор да го цитирате или поврзете овој запис:
http://hdl.handle.net/20.500.12188/21460
Наслов: | DETERMINATION OF SOME PESTICIDE RESIDUES IN APPLE JUICE BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY | Authors: | Velkoska-Markovska, Lenche Petanovska-Ilievska, Biljana Markovski, Aleksandar |
Keywords: | RP-HPLC, SPE, method development, validation | Issue Date: | 2019 | Publisher: | University Ss. Cyril and Methodius in Skopje | Journal: | Journal of Agricultural, Food and Environmental Sciences | Abstract: | A new, simple and reliable reversed-phase high-performance liquid chromatography (RP-HPLC) method for determination of 2,4-D ((2,4-dichlorophenoxy)acetic acid), atrazine, malathion, fenitrothion and parathion residues in apple juices has been developed and validated. Successful separation and quantitative determination of analytes were performed on Purospher STAR RP-8e (30 x 4 mm, 3 µm) analytical column, with mobile phase consisted of acetonitrile/water (45/55, V/V), flow rate of 1 mL/min, constant column temperature at 25 0C and UV detection at 220 nm and 270 nm. A solid-phase extraction (SPE) was used for concentration and clean-up of analytes. Specificity, selectivity, linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ) were tested for the method validation according to European Commission guidelines for pesticide residue analytical methods, and all performance characteristics were found within acceptance criteria. Calibration curves were linear within the range less than 50 % of the maximum residue limit (MRL) values and 20 % above for all investigated pesticides (R2 > 0.95). Under the stipulated conditions, values for relative standard deviations (RSD) of retention times and peak areas were 0.12 % - 0.28 % and 0.08 % - 8.50 %, respectively. The obtained values for recoveries ranged from 93.65 % - 118.62 %, with RSD ≤ 5.64 %. This method was successfully applied for determination of investigated pesticide residues in apple juice samples, which were taken from Macedonian markets. The run time of assay obtained from this chromatography condition was about 4 min. | URI: | http://hdl.handle.net/20.500.12188/21460 | DOI: | 10.55302/jafes19733030vm |
Appears in Collections: | Faculty of Agricultural Sciences and Food: Journal Articles |
Files in This Item:
File | Опис | Size | Format | |
---|---|---|---|---|
apple juice 73 3 2019.pdf | 523.19 kB | Adobe PDF | View/Open |
Page view(s)
38
checked on 24.7.2024
Download(s)
11
checked on 24.7.2024
Google ScholarTM
Проверете
Altmetric
Записите во DSpace се заштитени со авторски права, со сите права задржани, освен ако не е поинаку наведено.